General Electric WB19K10088 Range Pilot Assembly

Special Price $77.29 Regular Price $97.95
In stock
Available Quantity:   11
SKU
WB19K10088

Product Description

The General Electric WB19K10088 Range Pilot Assembly, works by engaging the gas valve and igniter, to make the burners light up when the machine is switched on. The assembly also consists of a pilot light that continuously ignites the burners used to regulate the ignition system of the gas ranges. This unit also increases the efficiency of cooking the flame is constantly on, and there is no accumulation of gas which may lead to an explosion, and no need for constant lighting. It controls the heat, reducing the risks of gas leakage to ignite the stove.
Pilot Lights,
Manufacturer
https://www.hnkparts.com/media/catalog/product/w/b/wb19k10088_general-electric_hnkparts.png
Manufacturer Name: GENERAL ELECTRIC
Product Number: WB19K10088
OEM Part Number: WB19K10088
Product Description: Pilot Assembly

Choose the best Home Appliance parts and supplies from HnKParts!

  • Same Day Shipping

  • Best Quality And Best Price

  • Wide Range of Inventory

  • Best Customer Service

Have More Questions or Need Help to Place The Order?
Reach us at (866)723-0907 or [email protected]

Write Your Own Review
You're reviewing:General Electric WB19K10088 Range Pilot Assembly
Your Rating
Customer Questions
What maintenance is required for the General Electric WB19K10088 Pilot Assembly?

Regularly inspect the pilot assembly for dirt, grease, or soot buildup. Clean gently with a soft brush and ensure connections are secure. Proper maintenance ensures consistent ignition, prevents gas flow issues, and promotes better operation. Avoid using chemicals near the flame.

What are common issues with the General Electric WB19K10088 Pilot Assembly?

  • Pilot flame not lighting consistently.
  • Weak or irregular flame.
  • Gas odor due to improper ignition.
  • Difficulty maintaining flame in windy or drafty conditions.

Installation Steps

Step1: Turn off gas supply shut main valve and unplug range.

Step2: Remove burner grate and access pilot assembly area carefully.

Step3: Disconnect old pilot assembly carefully using proper tools.

Step4: Install new pilot assembly securely in position.

Step5: Reconnect gas line and check all fittings tightly.

Step6: Restore power test ignition and check for gas leaks.

Step7: Ensure proper flame and monitor operation for safety.