Bard Manufacturing SP21058 Pilot Assembly Replacement Kit

Special Price $150.56 Regular Price $180.19
In stock
Available Quantity:   2
SKU
SP21058

Product Description

The Bard Manufacturing SP21058 Pilot Assembly Replacement Kit used for flame supply to the water heater’s burner to ensure proper ignition. It supplies gas through the pilot tube while the thermocouple ensure that the flame is on or off. In case the flame is extinguished, the thermocouple triggers the gas valve to close to prevent further usage. This kit also helps maintain the system's consistent heating performance and improve efficiency.

Manufacturer
Manufacturer Name: BARD MANUFACTURING
Product Number: SP21058
OEM Part Number: SP21058
Product Description: Pilot Assembly Replacement Kit

Choose the best Home Appliance parts and supplies from HnKParts!

  • Same Day Shipping

  • Best Quality And Best Price

  • Wide Range of Inventory

  • Best Customer Service

Have More Questions or Need Help to Place The Order?
Reach us at (866)723-0907 or [email protected]

Write Your Own Review
You're reviewing:Bard Manufacturing SP21058 Pilot Assembly Replacement Kit
Your Rating
Customer Questions
What maintenance is required for the Bard Manufacturing SP21058 Pilot Assembly Replacement Kit?

Regularly inspect the pilot assembly for dirt, dust, or soot buildup. Clean the pilot tip gently with a soft brush and ensure connections are secure. Proper maintenance avoids ignition issues and ensures better, more efficient operation of the appliance.

What are common issues with the Bard Manufacturing SP21058 Pilot Assembly Replacement Kit?

  • Failure to ignite or inconsistent flame.
  • Soot or debris blocking the pilot.
  • Loose or corroded connections.
  • Gas leaks if improperly placed.

Installation Steps

Step1: Turn off gas and electrical power supply; allow unit to cool completely before servicing.

Step2: Remove access panel and carefully disconnect old pilot assembly from gas line and mounting bracket.

Step3: Install new pilot assembly, align properly, and secure fittings and connections firmly.

Step4: Reconnect lines, ensure tight seal on all joints, and check for gas leaks.

Step5: Restore power, ignite system, and test flame for stable operation.