The Broan S97011810 Range Thermal Cutoff Protector used to shut off the circuit when the temperature rises beyond a certain limit. It works by regulating the temperature and cutting off the power supply in case of any hazardous conditions. This automatic cutoff mechanism is useful in preventing the internal parts of the appliance from getting damaged and increasing the life of the appliance. This thermal protector ensures that the performance of the kitchen ventilation systems is optimum.
Manufacturer
https://www.hnkparts.com/media/catalog/product/s/9/s97011810-92832.jpg

This Part Fits the Following Models (4)

Manufacturer Name: Broan
Product Number: S97011810
OEM Part Number: S97011810
Product Description: Thermolink Protector

Choose the best Home Appliance parts and supplies from HNKParts!

  • Same Day Shipping

  • Best Quality And Best Price

  • Wide Range of Inventory

  • Best Customer Service

Have More Questions or Need Help to Place The Order?
Reach us at (866)723-0907 or [email protected]

Write Your Own Review
You're reviewing:Broan S97011810 Range Thermal Cutoff Protector
Your Rating
Customer Questions
What maintenance is required for the Broan S97011810 Thermal Cutoff Protector?

Regularly inspect the range thermal cutoff protector for signs of wear, overheating, or loose connections. Ensure surrounding components are clean and free of grease buildup to prevent overheating. Avoid exposure to moisture or damage during cleaning. Always disconnect power before servicing for safety.

What are common issues with the Broan S97011810 Thermal Cutoff Protector?

  • Failure to shut off during overheating conditions.
  • Electrical discontinuity or blown cutoff.
  • Loose or corroded wiring connections.
  • Intermittent power loss to range components.
  • Damage from excessive heat exposure.

Installation Steps

Step1: Turn off power at the breaker and confirm the unit is completely de-energized for safety.

Step2: Remove the fan or heater cover to access the internal thermal cutoff assembly.

Step3: Disconnect the wiring terminals from the old thermal cutoff protector.

Step4: Unscrew or unclip the faulty unit and remove it from its mounting position.

Step5: Install the new thermal cutoff protector in the same position and secure it firmly.

Step6: Reconnect wiring terminals exactly as originally placed.