Midea 17131000019587 Refrigerator Variable Frequency Driver Board

$60.70
In stock
Available Quantity:   128
SKU
17131000019587

Product Description

The Midea 17131000019587 Refrigerator Variable Frequency Driver Board is an electronic control board that controls the speed of the compressor and fan motors to control cooling output. It mainly works with changing power frequency depending on the needs of the system, it can operate at varying speeds rather than cycling. The mechanism has a driver circuit that on sensor signals and provides controlled electrical indications to connected motors. It is mounted in the control compartment and is wired up by special harnesses. This board assists in maintaining the constant temperature, minimizing fluctuations of power, and providing efficient and responsive work of the system in the normal mode.
Manufacturer
https://www.hnkparts.com/media/catalog/product/1/7/17131000019587-47706.jpg

This Part Fits the Following Models (2)

Write Your Own Review
You're reviewing:Midea 17131000019587 Refrigerator Variable Frequency Driver Board
Your Rating
Customer Questions
What maintenance is required for the Midea 17131000019587 Variable Frequency Driver Board?

Ensure adequate ventilation around the board to prevent overheating. Keep the housing dry and free from dust accumulation. Verify that wiring harnesses are properly secured. Monitor compressor performance periodically to ensure stable speed control and efficient operation.

What are common issues with the Midea 17131000019587 Variable Frequency Driver Board?

  • Compressor speed fluctuating irregularly.
  • Board failing to regulate frequency.
  • Cooling performance becoming inconsistent.
  • Communication errors with main control.

Installation Steps

Step1: Disconnect the refrigerator power supply for safety.

Step2: Remove the rear access cover to remove the control compartment.

Step3: Carefully unplug all wiring connectors from the existing driver board.

Step4: Unscrew and detach the old board from its mounting points.

Step5: Install the new board and secure it firmly in position.

Step6: Reconnect wiring, reinstall cover, restore power, and verify normal operation.