Product Description

The Carrier LH33ZG001 Silicone Nitride Hot Surface Ignitor is a high-temperature ignition element that is utilized in compatible gas furnaces and heating systems. Its primary purpose is to heat up quickly to the point where the fuel-air mix in the burner assembly is heated when the system needs heat. The ignitor is made of silicone nitride ceramic and is mounted close to the burner outlet and is connected to the ignition control circuit of the furnace. It assists in maintaining reliable ignition, supports maintaining consistent performance with start-up in the system and maintains reliable use.
Manufacturer
Manufacturer Name: RELIABLE PARTS SUPPLIER
Product Number: LH33ZG001
OEM Part Number: LH33ZG001
Product Description: Ignitor

Choose the best Home Appliance parts and supplies from HNKParts!

  • Same Day Shipping

  • Best Quality And Best Price

  • Wide Range of Inventory

  • Best Customer Service

Have More Questions or Need Help to Place The Order?
Reach us at (866)723-0907 or [email protected]

Write Your Own Review
You're reviewing:Carrier LH33ZG001 Silicone Nitride Hot Surface Ignitor
Your Rating
Customer Questions
What maintenance is required for the Carrier LH33ZG001 Ignitor Silicone Nitride?

Regularly inspect the ignitor for cracks or discoloration and ensure electrical connections are secure. Keep the surrounding area clean of debris to prevent overheating. Handle carefully to avoid damage, and always follow safety precautions when the system is powered off.

What are common issues with the Carrier LH33ZG001 Ignitor Silicone Nitride?

  • Ignitor failing to spark or ignite consistently.
  • Cracks or breakage due to thermal stress.
  • Electrical connection issues causing intermittent operation.
  • Overheating or discoloration affecting performance.

Installation Steps

Step1: Turn off power and gas supply to the furnace and confirm the unit is completely de-energized.

Step2: Remove the furnace access panel to expose the burner and ignitor assembly.

Step3: Locate the existing hot surface ignitor mounted near the burner section.

Step4: Carefully disconnect the wiring harness, avoiding any force on the element.

Step5: Remove the mounting screws and gently take out the old ignitor without touching the heating surface.

Step6: Install the new ignitor in the same position and secure it with screws, ensuring proper alignment with the burner.

Step7: Reconnect wiring, reinstall the access panel, restore power and gas, and test ignition cycle for safe operation.