The LG AJU34125555 Water Inlet Valve is used to regulate the water supply from the refrigerator to the ice maker and water dispenser. Designed to control the water pressure and flow to ensure that there is no leakage and that the system is performing efficiently. Works through opening and closing of its solenoid valves by electrical signals from the appliance, permitting water flow. This control makes it possible to avoid over-flooding and also to make better use of water in the system.
Water Inlet Valve,
Manufacturer
✓ This Product Replaces: AJU34125548
https://www.hnkparts.com/media/catalog/product/a/j/aju34125555-44750.jpg
Manufacturer Name: LGE
Product Number: AJU34125555
OEM Part Number: AJU34125555
Product Description: Valve Assy-Water

Choose the best Home Appliance parts and supplies from HnKParts!

  • Same Day Shipping

  • Best Quality And Best Price

  • Wide Range of Inventory

  • Best Customer Service

Have More Questions or Need Help to Place The Order?
Reach us at (866)723-0907 or [email protected]

Write Your Own Review
You're reviewing:LG AJU34125555 Refrigerator Water Inlet Valve Assembly
Your Rating
Customer Questions
What maintenance is required for the LG AJU34125555 Water Inlet Valve Assembly?

Check that water supply lines are tightly connected and free from mineral buildup. Ensure the valve opens and closes smoothly during cycles. Clear any debris from the inlet screen to maintain steady flow. Operate the ice maker and water dispenser periodically to confirm consistent function.

What are common issues with the LG AJU34125555 Water Inlet Valve Assembly?

  • No water reaching ice maker.
  • Slow water flow at dispenser.
  • Valve not opening properly.
  • Intermittent filling of ice tray.

Installation Steps

Step1: Unplug the refrigerator and shut off the water supply.

Step2: Remove the rear access panel to locate the valve.

Step3: Disconnect water lines and electrical connectors.

Step4: Unscrew and remove the old valve assembly.

Step5: Install the new valve and reconnect lines securely.

Step6: Reassemble the panel, Restore water and power, then inspect for leaks.