LG 5221ER1003S Washer Inlet Valve Assembly

Special Price $72.00 Regular Price $95.23
In stock
Available Quantity:   514
SKU
5221ER1003S

Product Description

The LG 5221ER1003S Washer-Inlet Valve Assembly controls the flow of hot and cold water into the washing machine and provides a proper water supply. This component regulates the water entry depending on the cycles and helps in the accurate filling. It works by controlling its solenoid valves that are connected to the washer and which opens and closes depending on the signals received. It is made for durability to reduce leakages and water pressure problems hence increasing the longevity of the machine.
Manufacturer
https://www.hnkparts.com/media/catalog/product/5/2/5221er1003s_lge_hnkparts.png
Manufacturer Name: LGE
Product Number: 5221ER1003S
OEM Part Number: 5221ER1003S
Product Description: Valve Assy-Inlet

Choose the best Home Appliance parts and supplies from HnKParts!

  • Same Day Shipping

  • Best Quality And Best Price

  • Wide Range of Inventory

  • Best Customer Service

Have More Questions or Need Help to Place The Order?
Reach us at (866)723-0907 or [email protected]

Write Your Own Review
You're reviewing:LG 5221ER1003S Washer Inlet Valve Assembly
Your Rating
Customer Questions
What maintenance is required for the LG 5221ER1003S Inlet Valve Assembly?

Regularly inspect the inlet valve for mineral buildup or debris in the screens. Tighten any loose fittings and check hoses for leaks. Run a monthly cold-water rinse cycle to flush sediments, ensuring proper water flow and avoiding pressure issues.

What are common issues with the LG 5221ER1003S Inlet Valve Assembly?

  • Water filling slowly.
  • Valve leaking during cycles.
  • Washer not starting fill.
  • Inconsistent water temperature.

Installation Steps

Step1: Unplug the washer and shut off the water supply valves.

Step2: Pull the washer away and remove the rear access panel.

Step3: Disconnect water hoses and electrical connectors from the old valve.

Step4: Remove mounting screws and take out the valve assembly.

Step5: Install the new valve, reconnect hoses and wiring securely.

Step6: Restore water and power, then check for leaks during a fill cycle.