LG 4681EL1009C Dryer Drum DC Motor Assembly

Special Price $243.84 Regular Price $321.95
In stock
Available Quantity:   12
SKU
4681EL1009C

Product Description

The LG 4681EL1009C Dryer Drum DC Motor Assembly serves to rotate the drum during the drying process. The motor in this assembly ensures smooth, and steady movement, which allows clothes to dry evenly and reduces damage. It works by changing electrical energy into rotation to move with accuracy, and little noise.
LG Dryer Parts, Motor,
Manufacturer
https://www.hnkparts.com/media/catalog/product/4/6/4681el1009c_lge_hnkparts.png

This Part Fits the Following Models (2)

Manufacturer Name: LGE
Product Number: 4681EL1009C
OEM Part Number: 4681EL1009C
Product Description: Motor Assy-Dc-Drum

Choose the best Home Appliance parts and supplies from HnKParts!

  • Same Day Shipping

  • Best Quality And Best Price

  • Wide Range of Inventory

  • Best Customer Service

Have More Questions or Need Help to Place The Order?
Reach us at (866)723-0907 or [email protected]

Write Your Own Review
You're reviewing:LG 4681EL1009C Dryer Drum DC Motor Assembly
Your Rating
Customer Questions
What maintenance is required for the LG 4681EL1009C Drum DC Motor Assembly?

Regularly inspect the dryer motor assembly for dust buildup and lint, as debris can affect performance and airflow. Ensure electrical connections are secure and free from corrosion or wear. Keep the surrounding place clean and well-ventilated to prevent overheating. Periodic checks support maintain efficiency and reduce the risk of motor strain or failure.

What are common issues with the LG 4681EL1009C Drum DC Motor Assembly ?

  • Motor failure causing the dryer drum not to rotate.
  • Unusual noises such as grinding or humming during operation.
  • Overheating leading to intermittent shutdowns.
  • Weak or inconsistent drum movement affecting drying performance.
  • Electrical connection faults causing startup issues.

Installation Steps

Step1: Turn off power and unplug dryer for safety.

Step2: Remove rear panel and access drum motor area.

Step3: Disconnect wiring harness and note connections carefully.

Step4: Unbolt and remove faulty motor assembly from mount.

Step5: Install new motor, secure bolts, reconnect wiring.

Step6: Reassemble panel and restore power to test operation.