Product Description

The Bosch 00605061 Range Two-Way Valve regulates the flow of gas between burner circuits according to the requirements of ignition and temperature. It moves to open and closed positions to direct fuel to the correct position in response to the control signals to produce safe, and efficient flames.
Water Inlet Valves,
Manufacturer
✓ This Product Replaces: 605061
https://www.hnkparts.com/media/catalog/product/0/0/00605061_bosch_hnkparts.png
Manufacturer Name: BOSCH
Product Number: 00605061
OEM Part Number: 00605061
Product Description: Valve-Two Way

Choose the best Home Appliance parts and supplies from HnKParts!

  • Same Day Shipping

  • Best Quality And Best Price

  • Wide Range of Inventory

  • Best Customer Service

Have More Questions or Need Help to Place The Order?
Reach us at (866)723-0907 or [email protected]

Write Your Own Review
You're reviewing:Bosch 00605061 Range Two Way Valve
Your Rating
Customer Questions
What maintenance is required for the Bosch 00605061 Valve?

Regularly inspect the range valve for gas leaks, corrosion, or blockages. Keep surrounding connections clean and tightly secured. Ensure proper used alignment to prevent stress on fittings. Always turn off gas supply before servicing and have a professional check it periodically for better operation.

What are common issues with the Bosch 00605061 Valve?

  • Gas leakage due to worn seals or loose fittings.
  • Valve failing to open or close properly.
  • Inconsistent gas flow affecting burner performance.
  • Internal blockage restricting gas passage.
  • Clicking sound without ignition due to valve malfunction.

Installation Steps

Step1: Turn off gas/electric supply and confirm zero pressure.

Step2: Remove access panel from range and locate existing valve assembly.

Step3: Disconnect old valve, noting hose and fitting positions.

Step4: Install new valve, ensuring correct orientation and secure fittings with proper torque.

Step5: Reconnect lines, check for leaks using approved leak solution, restore power, test operation.

Step6: Wear protective gloves and ensure ventilation during installation for safety.